TM 9-4110-256-14
Table 2-1. Preventive Maintenance Checks and Services for Model F1000RE
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
Refrigeration
Unit Interior
WARNING
High voltage and exposed rotating parts
are contained in the refrigeration unit.
Personal injury can result if power is
connected.
29
Monthly
Dehydrator
of refrigerant leak. If damaged or evidence of
evidence of leak is found.
leaking found, notify direct support maintenance
to replace it.
30
Monthly
Gages
Inspect the gages for evidence of refrigerant
Evidence of leak is found.
leak. If damaged or evidence of leaking found,
notify direct support maintenance to replace it.
31
Monthly
Receiver
Inspect the receiver for damage and evidence of
Receiver is damaged or
refrigerant leak. Inspect the isolation valves
evidence of leak is found.
for evidence of refrigerant leak. If damaged or
evidence of leaking found, notify direct support
maintenance to replace it.
32
Monthly
Pressure
Inspect the pressure regulator valves for damage
Pressure regulator valve
Regulator
or evidence of refrigerant leak. If damaged or
damaged or evidence of
Valves
evidence of leaking found, notify direct support
leak is found.
maintenance to replace it.
33
Monthly
Metal Hose
Inspect the metal hose assemblies for kinks or
Metal hose assembly
Assemblies
evidence of refrigerant leak. If damaged or
kinked or evidence of leak
evidence of leaking found, notify direct support
is found.
maintenance to replace it.
34
Monthly
Valves
Inspect the valves for evidence of refrigerant
Evidence of leak is found.
leak. If evidence of leaking found, notify direct
support maintenance to replace it.
35
Monthly
Sight
Inspect the sight indicator for evidence of
Evidence of leak is found.
Indicator
refrigerant leak. If evidence of leaking found,
notify direct support maintenance to replace it.
2-16