TM 9-4110-256-14
Table 2-1. Preventive Maintenance Checks and Services for Model F1000RE
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
Refrigeration
Unit Interior
WARNING
High voltage and exposed rotating parts
are contained in the refrigeration unit.
Personal injury can result if power is
connected.
24
Weekly
Push Switches
a.
Inspect the push switches for cracked
The push switches stick.
(Side
case and loose or missing attaching
Wire lead frayed or
hardware. If damaged or loose, notify
broken.
Doors)
unit maintenance to tighten or replace it
as necessary.
b.
Inspect the push switches for smooth
operation. If binding, notify unit
maintenance to test and replace it as
necessary.
c.
Inspect the push switches for frayed or
broken wire leads. If damaged, notify
unit maintenance to repair or replace it
as necessary.
Refrigeration
Unit Exterior
25
Monthly
a.
Inspect the panel for any cracks, tears,
Panel
and loose or missing hardware. If
cracked, notify direct support
maintenance for repair. If hardware is
loose or missing, notify unit maintenance
to tighten or replace it as necessary.
b.
Inspect for any chipped or missing paint
and evidence of corrosion. If paint is
damaged or frame shows evidence of
corrosion, notify unit maintenance to
paint it.
2-14