TM 9-4110-256-14
Table 4-3. Wire List
TERMINATION
TERMINATION
AWG WIRE
LENGTH
SIZE
FROM
TERMINAL
TYPE
TO
TERMINAL
TYPE
IN.
CM
TB2-B
CB1-B1
MS25036-112
10 AWG-WHT
60.00
152.40
TB2-C
CB1-C1
MS25036-112
10 AWG-WHT
60.00
152.40
TB2-N
TB1-1
MS25036-112
10 AWG-WHT
60.00
152.40
GND
MS25036-102
TB1-2
MS25036-112
10 AWG-WHT
60.00
152.40
GND
MS25036-102
FR GND
MS25036-157
10 AWG-WHT
24.00
60.96
NOTE
1 Type SO Cable, Conductor Size 12-4, 20 Amps Min. Rating 250 Vac.
2 Type SO Cable, Conductor Size 14-4, 15 Amps Min. Rating 250 Vac.
c.
Removal.
(1)
Tag and disconnect wire lead(s) from component.
(2)
Remove tiedown straps and loosen clamp(s) as necessary to remove wire(s).
(3)
Remove any silicone RTV remaining in evaporator frame grommets (4).
d. Installation.
(1)
Carefully route wire lead(s) through clamp(s) and grommet(s) as necessary.
(2)
Connect wire lead(s) to component using tags and wiring diagram (fig. 1-4). Remove tags.
(3)
Install tiedown straps as necessary and tighten any clamp(s) that were loosened for removal.
(4)
Apply silicone RTV into evaporator frame grommets (4) to seal evaporator enclosure.
(5)
Close control box cover (3). Install two new lock washers (2) and bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Close control panel cover.
Close enclosure assembly if open.
Connect power and put unit back into service.
4-40