TM 9-4110-256-14
4-20. WIRES, CABLES, AND HARNESSES TESTING, REPAIR, AND REPLACEMENT.
This task covers:
a. Testing
b. Repair
c. Removal
d. Installation
INITIAL SETUP
Tools:
Equipment Conditions:
Heat Gun
power disconnected.
Electrical Connector Repair Tool Kit
Control panel cover open.
Enclosure assembly open if needed.
Materials/Parts:
General Safety Instructions:
Wire (As Required)
WARNING
Insulation Sleeving (As Required)
High voltage and exposed rotating parts
are used in the refrigeration unit.
Personal injury can result if power is
connected.
Marker Tag(s) (As Required)
Tiedown Strap(s) (As Required)
Silicone RTV
a. Testing.
(1) Be sure power has been disconnected at the source and remove two bolts (1) and lock washers (2). Open
control box cover (3). Discard lock washers.
(2) Tag and disconnect wire leads from components as necessary to isolate the wire or harness being tested.
(4) Replace any wire lead(s) that do not show continuity.
(5) Connect wire lead(s) per tag and wiring diagram (fig. 1-4).
4-35