TM 9-4110-256-14
(2) Remove any remaining rivet material.
(3) Install new rivet or blind rivet nut as required.
(4) Defrost Tube And Bracket Assembly Removal.
NOTE
Remove only items necessary to replace damaged component(s).
(a) Remove hose clamp (1) and plastic tubing (2).
(b) Remove self locking nut (3), bolt (4), and clamp (5). Discard self locking nut.
(c) Remove two bolts (6), lock washers (7), and defrost tube bracket (8). Discard lock washers.
(d) Remove grommet (9).
(e) Remove any silicone RTV remaining in grommet (9).
NOTE
Remove only items necessary to replace damaged component(s).
(f) Remove 12 self locking nuts (10), bolts (11), and four unit mounts (12). Discard self locking nuts.
NOTE
Heat shield assembly will be loose when evaporator housing is removed.
(g) Remove 34 self locking nuts (13), bolts (14), evaporator housing (15), and heat shield assembly (16).
Discard self locking nuts.
(h) Remove 34 screws (17) and heat shield panel (18).
(i) Remove eight screws (19), four heat shield beams (20) and (21), and heat shield insulation (22).
5-80