TM 9-4110-258-13
5.4 CIRCUIT BREAKER COVER REPAIR.
This task covers:
Repair
INITIAL SETUP
Tools:
Equipment Conditions:
Brush
Circuit breaker cover removed.
1, Section III, Appendix B
Materials/Parts:
Torch Set
1, Section III, Appendix B
Gaskets (2)
General Safety Instructions:
Gaskets (2)
WARNING
General Purpose Adhesive
Acetone and methyl-ethyl ketone (MEK) are
flammable and their vapors can be explosive.
Wiping Rag
Repeated or prolonged skin contact or
inhalation of vapors can be toxic. Use in a
Acetone
well ventilated area, wear gloves, and keep
away from sparks or flame.
Methyl-Ethyl Ketone
Repair.
(1) Remove as much old gasket material (1) or (2) as possible by pulling or scraping it away from the circuit breaker
cover (3).
Figure 5-2. Circuit Breaker Cover.
5-5