TM 9-4110-258-13
5.7 SERVICE MANIFOLD INSTALLATION.
This task covers:
a. Repair
b. Removal
INITIAL SETUP
Tools:
General Safety Instructions:
Gloves
WARNING
1, Section III, Appendix B
Goggles
Sudden and irreversible tissue damage
1, Section III, Appendix B
can result from freezing. Wear gloves and
Refrigerant Recovery and Recycle Unit
face protector or safety glasses in any
5, Section III, Appendix B
situation where skin or eye contact with
refrigerant is possible.
Equipment Conditions:
Heat may cause the refrigerant to
disconnected.
decompose and release irritating, toxic,
Both side doors open.
and corrosive gases. Prevent contact of
Front door open.
refrigerant with flame or hot surfaces.
General Safety Instructions:
Compressor lubricating oil is caustic.
Wear gloves and a face protector or
WARNING
safety glasses in any situation where skin
or eye contact is possible. If oil does
High voltage and rotating parts are used
contact skin, wash with soap and water.
in the refrigeration unit. Personal injury
can result if power is connected.
Dangerous chemical refrigerant under
pressure is used in the operation of this
equipment. Use great care to avoid
contact with liquid refrigerant. Work in
a well ventilated area.
a. Installation.
CAUTION
Using excessive force when opening or closing valves can cause damage to the valve seats.
NOTE
The compressor shut off valves can be adjusted to three positions, fully closed to block the
refrigerant tubes and isolate the compressor and service port, fully open to allow flow from piping
to compressor but not the service port, and cracked (one turn closed from fully open) to allow flow
from piping to compressor and service port on valve.
(1) Remove two shut off valve caps and turn the shut off valves fully counterclockwise to backseat them.
5-8