STRAINER REPLACEMENT
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
Materials/Parts
Lock Washers (4)
Refrigeration system discharged (para 5.13).
Right and left side door open.
a. Removal.
(1) Loosen two flare nuts (1).
NOTE
Note flow direction prior to removal.
(2) Remove bolt (2), lock washer (3), clamp (4), and strainer (5). Discard lock washer.
(3) If strainer bracket (6) is damaged, remove two bolts (7) and strainer bracket.
Figure 5-11. Strainer