TM 9-4120-388-14
5-28. CONDENSER COIL - Continued.
b. Repair.
(1) Repairs are limited to straightening of mashed fins and repair or replacement of brackets.
(2) If fins are mashed or dented so that air flow across coil would be blocked, straighten them using a plastic
fin comb.
c.
Installation.
When handling coils, wear gloves to avoid cuts and reduce damage on the coil.
Loosely attach brackets to coil with eight flat head screws. Do not tighten screws.
(1)
Carefully slide condenser coil and brackets into unit and align side mounting holes.
(2)
Secure brackets to casing side panels with eight pan head screws.
(3)
(4) Tighten eight flat head screws in condenser flanges.
While purging the system with nitrogen, braze the tube joints in position noted at disassembly. (See para
(5)
(6)
(7)
(8)