TM9-4120-398-14
Dry cleaning solvent (Federal Specification P-D-680) used to clean parts is potentially dangerous to
personnel and property. Do not use near open flame or excessive heat. Flash point of solvent is 100 F
to 138F (38 C to 59 C).
adhesive.
(c) Coat the mating surfaces of the metal and gasket with adhesive (item 1 Appendix E). Let both surfaces
air dry until the adhesive is tacky but will not stick to fingers.
(d) Starting with an end, carefully attach the gasket to the metal. Press into firm contact all over.
c. Installation.
(1) Aline the hinge holes with the frame holes.
(2) Insert and set the five blind rivets.
(3) Close the door and tighten the two turnlock fasteners.