TM9-4120-398-14
4-15. CONDENSER OUTLET PANEL AND GRILLE (cont)
(3) To replace gasket:
(a) Remove as much old gasket material as possible by pulling or scraping it away from the metal surface
WARNING
Dry cleaning solvent (Federal Specification P-D-680) used to clean parts is potentially dangerous to
personnel and property. Do not use near open flame or excessive heat. Flash point of solvent is 100 F
to 138 F (38 C to 59 C).
adhesive.
(c) Coat the mating surfaces of the metal and gasket with adhesive (item 1 Appendix E). Let both surfaces
air dry until the adhesive is tacky but will not stick to fingers.
(d) Starting with an end, carefully attach the gasket to the metal. Press into firm contact all over.
c. Installation.
Aline the grille mounting holes with the frame holes.
(1)
Install 10 tapping screws (6) in the grille (5).
(2)
Place the condenser outlet panel (2) in position and insert the nine blind rivets (3) holding the top hinge (4).
(3)
Tighten six stud fasteners (1) to hold the condenser outlet panel (2).
(4)