TM 9-4120-399-14
4-24. INFORMATION PLATES.
This Task Covers:
b. Inspection
c. Installation
a. Removal
Initial Setup:
Tools Required
Tool kit, Refrigeration
Material's Required
None
Equipment Condition
Air conditioner shut down and cool.
a. Removal.
(1) Remove six rivets (1) and information plate (2) from front of unit.
(2) Remove twenty-four rivets (3) and information plates (4), (5), (6), (7), (8), (9), (10)
and (11).
(3) Remove set screw (12) and mode select knob (13).
(4) Remove set screw (14) and temperature control knob (15).
CAUTION
Damage to electrical wiring can occur if drill bit
enters too deeply into control module. Be sure to
allow drill to only enter .12 inch into control module.
(5) Remove six rivets (16) and control module information plate (17).
b. Installation.
(1) Install control module information plate (17) and six rivets (16).
CAUTION
Damage to electrical wiring can occur if drill bit
enters too deeply into control module. Be sure to
allow drill to only enter .12 inch into control module.
(2) Install temperature control knob (15) and set screw (14).
(3) Install mode select knob (13) and set screw (12).