TM9-4120-400-14
4-14.
SUPPLY AIR LOUVER. - continued
REMOVAL
Remove six screws (1) and lock washers (2) and pull louver (3) from the unit.
Dry cleaning solvent used to clean parts is potentially dangerous to personnel and
property. Do not use near open flame or excessive heat. Use in well ventilated area.
CLEANING
1.
Usually it is only necessary to wipe or brush dirt from louver.
2.
If louver is extremely dirty, immerse in a detergent solution or dry cleaning solvent.
Agitate until dirt is removed, using a soft brush if necessary to loosen caked-on dirt,
3.
4.
Rinse in clean water or clean dry cleaning solvent.
Dry thoroughly.
5.
INSTALLATION
Secure louver (3) with screws (1) and lock washers (2).
NOTE
FOLLOW-ON MAINTENANCE:
Connect power at power source.
I N F O R M A T I O N PLATES.
b. Removal
c. Installation
a. Inspection
This task covers:
INITIAL SETUP
Tools
Materials/Parts
Drive screws (20)
Refrigeration Unit Service Tool Kit
Electrical Schematic Plate
Fluid Diagram Plate
Drill
Identification Plate
Danger Plate
Drill set
Equipment Condition
Disconnect power at power source.
4-46