CONDENSER AIR DISCHARGE LOUVER AND LINKAGE. - continued
3. Louver, linkage assembly, and cable installation.
Install one nut (13) 1/2 inch from each end of cable (12).
a.
Insert cable (12) into retaining brackets.
b.
Install nuts (13) on each end of cable (12) and tighten.
c.
Install clamp (16), screw (14), and lock washer (15).
d.
Slide louver assembly into unit and secure with four screws (8), lock washers (9), and two snap
e.
fasteners(10).
Insert push-pull control cable wire end through mechanical post (1).
f.
Insert end of wire thru mechanical post(11 ) and tighten screw(11 ) at actuating cylinder end.
g.
h.
Close louvers and pull control cable wire (3) tight with needle nose pliers and tighten mechanical post
screw (1).
NOTE
FOLLOW-ON MAINTENANCE:
FRESH AIR DAMPER AND ACTUATOR.
This task covers:
a. Cleaning
b. Inspection
INITIAL SETUP
TOOIS
Equipment Condition
Refrigeration Unit Service Tool Kit
Materials/Parts
Rags