TM 9-4120-401-14
INSTALLATION INSTRUCTIONS. - continued
4-5.
(3) Some installations require removal of the condenser side fabric cover. This generally applies only
when the air conditioner is positioned inside with condenser and fresh air openings ducted to the outside.
NOTE
If air conditioner is to be installed with condenser side (rear) exposed, the fabric
cover should be left in place if possible.
(a) Using screwdriver, remove six screws (1), lock washers (2), and flat washers (3). (See figure 4-4.)
(b) Carefully remove the fabric cover and store in a safe place for future use.
(c) Reinstall six screws (1), lock washers (2), and flat washers (3).
(4) No other preparation is necessary if the air conditioner is to be installed by the typical exterior wall
opening method and operated as a self-contained unit.