TM
9-4120-401-14
This task covers:
a. Repair
b. Replace
INITIAL SETUP
Tools
Materials/Parts
Refrigeration Unit Service Tool Kit
Insulation/Gasket
Adhesive Remover
Torch Set
Adhesive
Rivet Gun
Gloves
Lifting Handles (4)
Rivets (As Required)
Brush
Blind Nuts (As Required)
Nut Plates (As Required)
Equipment Condition
Use disconnect switch (NOT POWER
CABLE) to disconnect power to unit.
Damage to cable connector pins will
result if cable is used.
Disconnect power at power source.
NOTE
Repairs are limited to rework of broken or cracked welds, straightening of bent or
dented sheet metal and replacement of handles, gaskets, insulation, and rivnuts
and some small sheet metal parts by drilling out rivets and installation of
replacement parts.
a. Repair.
(1) Disassemble unit as necessary and make repairs as indicated.
(2) Minor dents and bent edges can be straightened using common sheet metal repair procedures.
(3) Should touch up or refinishing be necessary, see TM 43-0139.
6-2