TM 9-4120-403-14
Figure 4-27. Junction Box Removal/Installation
Removal
(1)
Place circuit breaker actuator arm in up position.
(2)
Unscrew four captive screws from flanges of junction box.
(3)
Carefully slide junction box outward.
(4)
Loosen screw in lower end fitting of circuit breaker control cable.
(5)
Remove two screws from clamps.
(6)
Slide actuator cable up and out.
(7)
Extend junction box out far enough to remove plugs P4, P8 and P10.
4-73