TM 9-4120-403-14
(8)
Remove four screws at flanges of control panel.
(9)
Support control panel so that capillary line and electrical harness will not be damaged.
(10) Tag and remove ground wires.
(11) Secure lower locknut, then remove nut, wires, and two washers from grounding stud E2.
(12) Remove two screws, flat washers, clamps and capacitor C4.
(13) Remove junction box.
Installation
(1)
Mount and secure control panel to junction box with four screws.
(2)
Slide capacitor C4 into two mounting clamps on junction box.
(3)
Tighten two screws on two capacitor mounting clamps.
(4)
Place junction box far enough in unit to attach ground wires.
(5)
Secure ground wires on grounding stud with two washers and locknut.
(6)
Secure junction box cover to junction box with four panel fastener screws.
(7)
Position loop clamps on cable assembly.
(8)
(9)
Secure loop clamps to junction box.
(10) Connect electrical plugs P4, P8 and P10.
(11) Position junction box in unit.
(12) Secure four panel fastener screws in flanges of junction box.
Follow-on procedure:
(1)
(2)
Connect power cord.
4-74