TM 9-4120-407-14
Table 3-2. Unit Preventive Maintenance Checks and Services for Model F36T-MPl - Cont
Location
Not Fully Mission Capable
Item
Item To
Interval
if:
No
Check/Service
Remove six screws (4), lock
12
Annually
Motor Controller
washers (5), flat
Assembly - Cont
washers (6), and cover (7).
Discard lock washers.
Check motor controller
If motor controller assembly
has been overheated.
assembly (8) for any visible
signs of overheating such as
burnt or discolored case.
Check motor controller
If motor controller assembly
is damaged.
assembly (8) case for any
visible damage such as dents
or tears.
If electrical leads are
Check motor controller
damaged.
assembly (8) electrical leads
for any damage such as
frayed or damaged
insulation or shielding.
Install cover (7), six screws (4),
new lock washers (5)
flat washers (6).
Install two screws (l), new lock
washers (2)
flat washers (3).
If motor controller assembly (8)
is damaged in any way or is
suspected to be defective,
notify Direct Support
Maintenance.
13
Annually
EMI Filters
EMI filter is damaged or
Check EMI filters (1) for any
visible damage such as
missing.
dents, swelling, or burns.
Test or replace as necessary
3-32