TM 9-4120-407-14
Table 3-2. Unit Preventive Maintenance Checks and Services for Model F36T-MPI - Cont
Location
Item
Item To
Not Fully Mission Capable
Interval
Procedures
Check/Service
No
if:
7
Panels/Covers -
(5) Wipe the panels/covers
Annually
Cont
with a clean dry rag until it
is thoroughly dry.
(6) Install the panels/covers per
If gasket material is suspected to
be damaged, check it per the
following:
(1) Remove panels/covers per
(2) Check if gasket material is
tom or missing.
(3) If no repair was necessary,
install the panels/covers per
Check that panels/covers are
Panels/covers loose or
securely attached. If loose,
missing.
secure them.
INTERIOR
NOTE
To prevent repeated removal and installation of items, the
following procedures must be performed to gain access to
the interior components.
Remove the air filters per
3-17, front panel
assembly
8
Fresh Air Damper
Annually
Turn fresh air damper knob (1) to
open and close damper door.
If damper door assembly is
damaged, repair or replace
3-28