TM 9-4120-407-14
(2) Rod. Arm. and Worm Gear.
(a) Remove Actuator Mounting Bracket Panel.
Be careful when moving refrigerant tubing, a kink or any other
damage can result in a leak or reduced refrigerant flow. Loosening
refrigerant tubing will result in loss of charge.
3 Remove two nuts (2) and carefully pull the actuating linear cylinder (3) out of the air
conditioner as far as the refrigerant tubing will allow. Do not disconnect refrigerant
tubing.
4 Remove eight screws (4) and panel (5).
Figure 3-23. Actuator Mounting Bracket Panel