TM 9-4120-407-14
3-28. ELECTRICAL COMPONENTS BRACKET REMOVAL.
This task covers:
a. Removal
b. Disassembly
c. Assembly
d. Installation
INITIAL SETUP
Tools
Equipment Conditions:
Service Refrigeration Unit Tool Kit
Material/Parts
a . Removal.
(1) Remove screw (1), lock washer (2), and flat washer (3). Discard lock washer.
(2) Remove two screws (4) and flat washers (5).
(3) Carefully pull the electrical components bracket (6) out of the air conditioner as far as the wire
leads will allow.
b. Disassembly.
NOTE
Disassemble only to the extent necessary for maintenance task being
performed.
(1) Remove three screws (7), lock washers (8), flat washers (9), and sheet (10). Discard lock washers.
(2) Remove screw (11), lock washer (12), flat washer (13) and strap (14). Discard lock washer.
(3) If complete disassembly/removal of the electrical components bracket (6) is necessary, remove the
individual components per the appropriate procedural paragraphs.
c. Assembly.
(1) If any components were removed from the electrical components bracket (6), install them per the
appropriate procedural paragraphs.
(2) Install strap (14), screw (11), new lock washer (12), and flat washer (13).
(3) Install sheet (10), three screws (7), new lock washers (8), and flat washers (9).
d. Installation.
(1) Carefully install the electrical components bracket (6) into the air conditioner.
(2) Install two screws (4) and flat washers (5).
(3) Install screw (1), new lock washer (2), and flat washer (3).
3-107