TM 9-4120-408-14
1-9. NOMENCLATURE CROSS-REFERENCE LIST. (Continued)
Table 1-1. Nomenclature Cross-Reference Limit. (Continued)
Common Name
Official Nomenclature
Fan Cutout Switch
Switch, Fan, Cutout
Indicator Lights
Diode Assembly, Light Emitting
Low-Pressure Switch
Switch, Low-Pressure Cutout
Mode Selector Switch
Switch, Rotary, Cam Actuated
Service Valve
Tee, Swivel, Access Valve
Thermoexpansion
Valve (TEV) Valve, Thermoexpansion
1-10. LIST OF ABBREVIATIONS.
All abbreviations, acronyms, signs, and symbols used in this manual are listed in the glossary (Section I), located in the
back of this manual.
1-11. GLOSSARY.
All terms used in this manual that are not defined in the Army Dictionary (AR 310-25) are defined in the glossary (Section
II), located in the back of this manual.
SECTION II. EQUIPMENT DESCRIPTION
1-12. EQUIPMENT CHARACTERISTICS. CAPABILITIES. AND FEATURES.
The air conditioner is a split pack unit that provides 30,000 British Thermal Unit per Hour (BTUH) cooling capacity. The
heating system of the shelter is incorporated with the control module to provide ease of operation of both heating and
cooling systems. The air conditioner operates on 28 volts direct current (VDC) at 66 amperes. The system is a sealed
unit and illuminates one of four warning lights on the control module should a problem occur. The air conditioner will also
automatically shut itself down to prevent further damage to the air conditioner or compressor. The compressor is not a
component of the air conditioner. The compressor is a component of the vehicle to which the air conditioner is mounted.
Refer to applicable technical manual for compressor information.
1-13. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS.
1-3, and table 1-4 list the major components and provide a
description of
each. The Item No. in
Table 1-2 relates to
the
1-3