TM 9-4120-408-14
5-13. LIQUID LINE RECEIVER MAINTENANCE.
This task covers:
Removal
Install
Inspect
INTAL SETUP
Tools
Materials/Parts (Continued)
Tool Kit, Service Refrigeration Unit,
Recovery and Recycling Unit, Refrigerant,
III, Item 9
Refer to TM 9-4120-408-24P for part
numbers of items to be replaced.
Manifold Gage, Charging and Testing,
Equipment Conditions
Item 17
Materials/Parts
5-7.
General Safety Instructions
Do not work on equipment without
following standard shop safety precautions.
CAUTION
Dehydrator must be replaced every time the air conditioner lines are exposed to the atmosphere.
Failure to obey this caution may result in equipment damage.
a. Inspect.
(1) Inspect liquid line receiver (Figure 5-8, 1) for leaks, cracks, bends, breaks, holes, and damaged or missing
fusible plug (2).
(2) Inspect all mounting hardware for damage.
(3) Replace all damaged or defective components.
b. Remove.
CAUTION
Remove fusible plug prior to removing liquid line receiver. Failure to do so may result in damage to
the equipment.
(2) Remove fusible plug (2) from liquid line receiver (1).
(3) Disconnect tubing (3) from liquid line receiver (1).
Change 5-29