TM 9-4120-408-14
Figure 6-2. Evaporator Housing Maintenance.
b. Repair.
(1) Inspect evaporator housing (1) for corrosion, cracks, bends, breaks, holes, severe damage, or missing rivnuts,
rivets, and self clinching studs.
(2) Inspect mounting feet (2) and handle (3) for damage.
(3) Replace damaged or missing mounting feet (2).
(4) Replace damaged handle (3) as follows:
(a) Remove and discard five rivets (4) and remove handle (3).
6-6