TM 9-4120-408-14
Figure F-15. Wiring Harness A106J1.
PROCEDURES:
b. Remove and discard electrical cable clamp (Figure F-15, 5), insulation sleeving (6), and insulation sleeving (7)
from connector (1) and wiring.
c. Remove faulty wire from wiring harness.
d. Refer to table F-23 to determine wire and cut wire to dimensions shown in Figure 15.
e. Refer to tables F-22 and F-23 to assemble wire. Mark wire with from to termination
designation
and
double
headed arrow on each end of wire assembly.
f. Install wire in connector (1).
g. Install new electrical cable clamp (5), insulation sleeving (6), and insulation sleeving (7), as shown in Figure F-
15, and heat shrink to a firm fit.
h Install tiedown straps at 3.00 inch maximum intervals and at each breakout.
F-24