TM 9-4910-387-14-2
6-2. TROUBLESHOOTING (cont)
A. WIRE MAY BE OPEN FROM MAIN POWER SOURCE TO FORWARD
B. FORWARD-OFF-REVERSE
SIDE OF STARTER. (cont)
SWITCH MAY BE DEFECTIVE.
NOTE
If the main drive motor
4.
Check for continuity. If
continuity does not exist, replace the wire (p 6-219).
starts when the FOR-
WARD-OFF-REVERSE
5. If main drive motor fails to start, proceed to step B.
switch is in REVERSE po-
sition, this shows that the
greatest portion of the
starting circuit is func-
tional.
1. Place the FORWARD-OFF-REVERSE switch in the REVERSE
position. Push START button. If main drive motor fails to start,
place the FORWARD-OFF-REVERSE switch back to FORWARD
position.
2. Connect one multimeter lead to
FORWARD-OFF-REVERSE switch
contact (1) and connect other lead to FORWARD-OFFREVERSE
switch contact (2). FORWARD-OFF-REVERSE switch is normally
open (N/O).
3. Check for continuity. If
continuity does not exist, replace the
4. If main drive motor fails to start, proceed to step C.
6-14