TM 9-4910-387-14-2
B.
MANIFOLD BULB ASSEMBLY MAY BE DEFECTIVE
.
NOTE
3 Check for continuity. If
continuity does not exist, replace the open
Wires at manifold bulb assembly are not tagged for
identification. To identify contact points for continuity checks,
follow wires from terminals. Remove tape and wire nuts from
4 If manifold bulb assembly is still inoperative, proceed to step B.
wire ends before performing continuity checks. After making
checks, replace wire nuts and apply tape (item 19, app C).
1 Remove cover from manifold bulb assembly.
wire from terminal A12 (1) is connected. Connect
the other lead to wire end where the wire from
terminal A14 (2) is connected.
2 Resistance should be
indicated. If no
resistance is
indicated, replace manifold bulb assembly (p 6-307).
6-45