TM 9-4910-387-14-2
6-2. TROUBLESHOOTING (cont) |
D. 24 VOLTS DC OUTLET ASSEMBLY MAY BE DEFECTIVE. (cont)
2 Connect one multimeter lead to the inner pin (2) of the 24 VOLTS
DC outlet assembly (3) and one lead to the threaded case (4) of the
24 VOLTS DC outlet assembly (3).
3 Check for continuity. If continuity is present, replace the 24 VOLTS
DC outlet assembly (3) (p 6-303). If continuity is not present, check
that wire is connected to inner pin (2).
4 If power is not present at 24 VOLTS DC outlet assembly, proceed to
step E.
E. WIRES MAY BE OPEN.
1 Connect one multimeter lead to starter center terminal (1) on the
forward side of the starter. Connect other lead in sequence to terminals
A7 (2), D6 (3), and C6 (4). Resistance will be indicated at terminal C6
(4).
6-68