TM 9-4910-387-14-2
NOTE
On newer tester models the red lead from A9 may be
connected to D12 and the black lead from A8 will be on
D15. However, this will not interfere with the operation
of the tester.
2 Remove both leads. Connect one multimeter lead to terminal C6 (4)
and connect other lead to contact (5) on 24-VDC switch.
3 Remove both leads. Connect one multimeter lead to contact (6) on
24-VDC switch. Connect the other lead in sequence to terminals
C14 (7), D14 (8), D12 (9), A8 (10), and to starter contact (11) on
forward side of starter.
6-69