Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
288.3
CIP
COUNTER INHIBIT(SEC) dial to 14.51.
SEQUENCE
Reading
288.4
CIP
RUN/HOLD OFF switch to RUN and observe the waveform drops to 0 Volts for 315 to 585 msec, then
304
AUTO 16
+0.3218 to +0.3258 Vdc
OSC
expands to 0.2 VP-P.
Replace card A1. Check A2 pin 62.
305
AUTO 6
+0.3485 to +0 529 Vdc
3
289
PPE
Set SEQUENCE switch to the positions indicated and observe the DMM reading for each switch setting.
Corrective action for steps 290 through 305 is: Replace card
* (See Step 174)
A1.
Check A1 pins 71 and 75.
SEQUENCE
Reading
306
CIP
RUN/HOLD/OFF switch to HOLD.
290
AUTO 1
+0.4216 to +0.4268 Vdc
307
CIP
COUNTER INHIBIT(SEC) dial to 16.01.
291
AUTO 7
+0.4216 to +0.4268 Vdc
308
CIP
RUN/HOLD/OFF switch to RUN.
292
AUTO
2
+0.3218
to
+0.3258
Vdc
308.1
CIP
Observe INHIB lamp illuminated.
293
AUTO
3
+0.3218
to
+0.3258
Vdc
308.2
CIP
RUN/HOLD/OFF switch to HOLD.
294
AUTO
4
+0.3218
to
+0.3258
Vdc
308.3
CIP
COUNTER INHIBIT (SEC) dial to 16.03.
295
AUTO
5
+0.3218
to
+0.3258
Vdc
308.4
CIP
RUN/HOLD/OFF switch to RUN and observe the waveform drops to 0 Volts for 315 to 585 msecs then
296
AUTO 8
+0.3218 to +0.3258 Vdc
OSC
expands to 0.2 VP-P.
Replace card A1. Check A2 pin 62.
297
AUTO 9
+0.3218 to +0.3258 Vdc
309
PPE
Set SEQUENCE switch to the positions indicated and observe the
298
AUTO 10
+0.3218 to +0.3258 Vdc
DMM reading for each switch setting. * (See Step 174)
299
AUTO 11
+0.3218 to +0.3258 Vdc
SEQUENCE
Reading
300
AUTO
12
+0.3218
to
+0.3258
Vdc
310
AUTO 1
+0.4216 to +0.4268 Vdc
301
AUTO
13
+0.3218
to
+0.3258
Vdc
Replace card A1. Check A1 pins 71 and 75.
302
AUTO
14
+0.3218
to
+0.3258
Vdc
303
AUTO
15
+0.3218
to
+0.3258
Vdc
3-87