Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D
Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE AC ION
T
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
1381
TP
MODE switch to L/R MVG.
1394
CIP
RUN/HOLD/OFF switch to HOLD.
1395
CIP
COUNTER INHIBIT(SEC) dial to 01.31.
Reference Sample Level Verification
1396
CIP
RUN/HOLD/OFF switch to RUN.
1397
DMM
Observe a reading of +0.5373 t +0.5427 Vdc.
1382
TP
Momentarily actuate TEST START switch.
(155)
1383
DMM
Observe a reading of -7.462 to -7.538 Vdc.
1398
CIP
RUN/HOLD/OFF switch to HOLD.
(152)
1399
CIP
COUNTER INHIBIT(SEC) dial to 01.71,
1384
TP
MODE switch to L/R STAT.
1400
CIP
RUN/HOLD/OFF switch to RUN.
1385
DMM
Observe a reading of -7.462 to -7.538 Vdc.
1401
MCP
Set SELECTOR A and MODE switches to the positions indicated
Troubleshoot S6 (MODE)
TP
switch circuit.
and observe the DMM reading for each series of switch settings.
1386
TP
MODE switch to UP/DN.
1387
DMM
Observe a reading of -7.462 to -7.53Vdc.
8
SELECTOR A
MODE
Reading
(153)
1402
H8
L/R STAT
+0.9870 to +0.9970 Vdc
1388
MCP
SELECTOR A switch to H8.
(156)
1389
TP
Set MODE switch to the positions indicated and observe the
DMM reading for each switch setting.
1403
L/R MVG
+1.970 to +1.990 Vdc
MODE
Reading
Replace Card A16. Check A16
1390
L/R MVG
+7.462 to +7.538 Vdc
pins 37, 78..
Replace card A16. Check A16 pin 37.
1404
H7
-1.970 to -1.990 Vdc
1391
L/R STAT
+7.462 to +7.538 Vdc
Replace card A16. Check A16
Troubleshoot S6 (MODE) switch circuit
pins 34 and 78.
1392
UP/DN
+3.980 to +4.020 Vdc
1405
L/R STAT
-0.9870 to -0.9970 Vdc
Replace card A16. Check A16 pin 29.
Replace card A16. Check A16
1393
DIVIDE 1
+2.487 to +2.513 Vdc
pins 34 and 78.
(154)
1406
CIP
RUN/HOLD/OFF switch to HOLD.
3-127