TM9-4935-481-14-1
Table 3-11. DMS-D
Performance Test-Continued
Table 3-11. DMS-D
Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
1491
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1509
TP
Momentarily actuate TEST START switch.
(168)
1510
CIP
Observe INHIB lamp illuminated before continuin
g.
1492
CIP
COUNTER INHIBIT(SEC) dial to 01.91.
1511
TP
Observe GO lamp extinguished a d NO GO lamp illuminated.
1493
MCP
DMM INPUT switch to SEL A.
(169)
1494
MCP
Adjust COMPARATOR THRESHOLD B ontrol to -1.980 0.005 Vdc.
c
1512
CIP
COUNTER INHIBIT(SEC) dial to 10.11.
DMM
1513
MCP
DMM INPUT switch to SEL A.
1495
MCP
DMM INPUT switch to DMM INPUT.
1514
MCP
Adjust COMPARATOR THRESHOLD B control to -0.9410 0.0020 Vdc.
1496
VWS
Adjust AMPTD(VOLTS) control to +2.02 0.001 Vdc.
0
DMM
DMM
1515
MCP
DMM INPUT switch to DMM INPUT.
1497
TP
Momentarily actuate TEST START switch.
1516
VWS
Adjust AMPTD(VOLTS) control to +1.110 0.001 Vdc.
1498
CIP
Observe INHIB lamp illuminated before continuing.
DMM
1499
TP
Observe GO and NO GO lamps illuminated.
1517
TP
Momentarily actuate TEST START switch.
(169)
1518
CIP
Observe INHIB lamp illuminated before continuing.
1500
VWS
Adjust AMPTD(VOLTS) control to +2.06 0.001 Vdc.
0
1519
TP
Observe GO and NO GO lamps illuminated.
DMM
(170)
1501
TP
Momentarily actuate TEST START switch.
1520
VWS
Adjust AMPTD(VOLTS) control to +1.129 0.001 Vdc.
1502
CIP
Observe INHIB lamp illuminated before continuing.
DMM
1503
TP
Observe GO lamp extinguished and O GO lamp illuminated.
N
1521
TP
Momentarily actuate TEST START switch.
(169)
1522
CIP
Observe INHIB lamp illuminated before continuing.
1504
VWS
Adjust AMPTD(VOLTS) control to +1.94 0.001 Vdc.
0
1523
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
DMM
(170)
1505
TP
Momentarily actuate TEST START switch.
1524
VWS
+DC/PULSE/-DC switch to +DC.
1506
CIP
Observe INHIB lamp illuminated before continuing.
1525
VWS
Adjust AMPTD(VOLTS) control to +0.7716 0.0002 Vdc.
1507
TP
Observe GO and NO GO lamps illuminated.
1526
TP
Momentarily actuate TEST START switch.
(169)
1527
CIP
Observe INHIB lamp illuminated before continuing.
1508
VWS
Adjust AMPTD(VOLTS) control to +1.90 0.001 Vdc.
0
1528
TP
Observe GO and NO GO lamps illuminated.
DMM
(170)
3-131