TM9-4935-481-14-1
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
CAUTION
TTS
Connect power cable to 115 Vac.
To avoid serious burns, avoid contacting the resistor body with bare fingers after connecting it
21
across the battery terminals in the following steps.
22
TTS
BATTERY CHARGE switch to ON.
Connect a 10 watt, 30 ohm resistor (5905-00-823-5450 or equivalent) (simulated normal load)
13
across the battery teminals and allow the battery to discharge for 30 seconds.
23
TTS
When FULL CHARGE lamp illuminates turn BATTERY CHARGE switch OFF, disconnect P1 and
P2 of the "E" cell synchronizer adapter, and the power cable of the TTS>
Monitor with the DMM probes (observing polarity across the battery.
14
Observe a reading > +9.6 Vdc
DMM
15
Remove the load and dispose of
the battery.
Remove the simulated load from the battery.
16
Repeat steps 13 through 16 for each battery.
17
MAIN POWER switch to OFF.
PP
18
"E" Cell Sync Procedure
NOTE
The "E" cell of the TTS must be synchronized when faulty batteries are replaced
with a full set or fully charged batteries.
TTS
Connect P1 of "E" cell synchronizer adapter to J1 of TTS.
19
20
TTS
Connect P2 of "E" cell synchronizer to J2 of TTS>
3-204