34. Cable receptacle, 26-pair,
p a r t i a l l y disassembled.
Warning: Resin No. 797 and cur-
ing agent No. 237 are harmful to
the skin. Wash thoroughly with
water any area of the body that may
have come in contact with the liquid
resin or curing agent.
(4). Pour 3 ounces of resin No. 797 for
each square foot of surface area to
26-pair, wiring diagram.
be covered into the mixing cup pro-
vided. S h a k e the can thoroughly
(c) For temperatures below 20 F,
before pouring out the resin. Tem-
fill the eye dropper to the red-
perature and climate will deter-
line with curing agent No. 237;
mine the quantity of curing agent
add the curing agent to the resin
and cold weather promoter to be
and mix thoroughly. Fill the eye
added to the resin. Use the eye
dropper to the redline with cold
dropper and prepare the mixture as
weather promoter No. 347. Add
follows:
the cold weather promoter to the
(a) For temperatures above 55 F,
combined curing agent and resin
fill the eye dropper to the red-
and mix thoroughly.
line with curing agent No. 237.
(5) Use the spatula (or the brush in
Add the curing agent to the resin
hard-to-reach areas or when the
and mix thoroughly.
temperature is above 55 F) and
(b) For temperatures between 20
spread a liberal coating of the pre-
and 55 F, fill the eye dropper to
pared mixture over the surface to
the redline with curing agent No.
be patched. Place the glass cloth
237. Fill the eye dropper to the
((3) above) over the coating and
halfway mark with cold weather
press it lightly with the applicator.
Spread a second liberal coating of
promoter No. 347. Add the cold
weather promoter to the com-
the mixture over the glass cloth;
bined curing agent and resin and
work from the center of the patch
mix thoroughly.
towards the edges.