TM 11-5895-463-15
(3) Install the separator with the leads
(6) Work the cable into the housing and
properly positioned.
lift and contact assembly out of the housing.
(4) Position the contact assembly near
(7) Slide the separator away from the
the housing and connect the leads.
contact assembly.
(5) Replace the contact assembly in the
(8) Tag and disconnect the leads.
housing. If necessary, work the cable out of the
(9) Remove the separator and slide the
housing to provide clearance for the contact
housing off the cable.
assembly.
(10) Slide the nylon insulator, enforcement,
(6) Be sure that the contact assembly is
locking ring, and cover off the cable.
properly seated and secure it to the housing
f. Replacement of 26-Pair Cable Connectors
with the contact assembly retaining screws.
(7) Slide the nylon insulator forward
(1) Slide the cover, locking ring, enforce-
until its flangle is flush against the housing.
ment, and nylon insulator on the cable. Be sure
(8) Slide the enforcement forward until
that the flange on the enforcement and nylon
its flange is flush against the nylon insulator.
insulator is toward the cable end.
( 9 ) Replace the sections of the cable
(2) Slide the housing on the cable.
clamp and secure them with the retaining bolts.