TM 5-1940-322-10
0049 00
MAINTENANCE PROCEDURES (Contd)
FILLING HYDROJET RESERVOIR
WARNING
Engine must be off and transmission must be in neutral
during filling. Failure to comply may result in injury or
death to personnel.
NOTE
1.
2.
View sight glass (2) to check oil level in reservoir (3).
3.
Remove reservoir fill cap (1) from reservoir (3).
4.
Fill oil until oil level reaches center of the sight glass (2).
5.
Install fill cap (1) on reservoir (3).
6.
1
2
~
3
END OF WORK PACKAGE
0049 00-16