TM 55-1925-282-14&P
0024 00
4. CLOSE, lock out, and tag out (FM 55-502) the applicable inlet sea water supply valve as shown in table 1.
5. Disconnect and free the stainless steel piping (figure 4, item 3) from the fittings (figure 4, item 4).
6. Disconnect and free the outlet hose (figure 4, item 5) from its fitting (figure 4, item 6).
7. On the flow control panel, loosen the two captive screws (figure 4, item 7), and open the flow control panel.
8. Remove the screw (figure 8, item 1) that secures the wire plug (figure 8, item 2) to the product water diverter
valve (figure 8, item 3).
9. Pull the wire plug (figure 8, item 2) straight off of the product water diverter valve (figure 8, item 3).
10. Label and disconnect the tubing (figure 8, items 4, 5 and 6) from the product water diverter valve (figure 8,
item 3).
11. Remove the four screws (figure 8, item 7) and four flat washers (figure 8, item 8) that secure the product
water diverter valve (figure 8, item 3) to its foundation (figure 8, item 9).
12. Remove the pipe fittings (figure 8, item 10) from the product water diverter valve (figure 8, item 3). Retain the
pipe fittings.
7
8
9
10
10
4
5
10
6
3
2
1
Figure 8. Product Water Diverter Valve
0024 00-18