14. Secure the fuel transfer pump (TM 55-1925-273-10).
15. Priming is now complete. CLOSE the valve opened in step 6 above and proceed to the Fuel Filter/Water
Separator Operation paragraph below.
FUEL FILTER/WATER SEPARATOR OPERATION
! CAUTION
Only one fuel transfer pump at a time may be operated while using the fuel filter/water
separator. Attempting to use two fuel transfer pumps will exceed the capacity of the fuel
filter/water separator and could result in damage to the fuel filter/water separator or to
the fuel transfer pumps.
1. Line up the fuel transfer system's valves to fill the desired tank (TM 55-1925-273-10).
2. At the 120V emergency distribution panel No. 1, set the RACOR FILTER circuit breaker (figure 2, item 1) to
the ON position.
1
ENGINE ROOM EMER
DIST PANEL NO. 1
Figure 2. 120V Emergency Distribution Panel No. 1