TM 9-1550-416-14&P
CAUTION
2-22. BATTERY CHARGING PROCEDURES
FOR TRANSMITTER AND GROUND SUP
Constant fast charging tends to deteriorate nicad
PORT EQUIPMENT (GSE) FIELD BOX
batteries in a very short time. Do not use fast
BATTERIES.
charging unless it is absolutely necessary.
Check the battery voltage level.
a.
NOTE
(1)
One, two or three transmitters and one or two CSE field
below 12 volts. Use the multimeter supplied with the GSE to
box batteries may be charged (either fast or standard)
determine the transmitter battery voltage. (See fig. 2-31.)
simultaneously or individually.
The GSE charger, when utilized for charging the FQM-
117 B-1 and FQM-117 C-1, system batteries (both
standard and fast charging) must be connected to a 110-
120 Vac power source.
When charging is complete, disconnect the equipment
from the charger to prevent discharge when the charger
is switched off.
(2) Charge the GSE field box battery if the voltage
level is below 12 volts. Use the multimeter supplied with the
GSE to determine the GSE field box battery voltage. (See fig.
Figure 2-32. Voltage checking of GSE field box battery.
b. Obtain the following equipment to perform the battery
WARNING
charging procedures.
One to three transmitters
During charging procedures, the metal portions
One or two GSE field boxes
of the ground support equipment charger case
GSE charger
will become hot. Avoid contact with the heated
Charge cables
surface as bums could result.
2-34