TM 9-1550-416-14&P
(6) Set GSE charger power switch to ON and
b. Obtain the following equipment to perform the bat-
charge batteries.
tery charging procedures:
1 to 12 Receiver and servo/battery
(a) For standard rate (overnight) charge, al-
group batteries
low batteries to charge at least 14 hours.
GSE charger
(b) For fast charging, turn on ac power, push
charger cables
button above receptacle for five seconds to start fast charge
c. Perform the battery charging procedures as outlined
and then connect battery to charge cable. The fast charge is
complete when the LED above the receptacle lights. No harm
(1) Ensure GSE charger power switch is set to
to the batteries will result if they are not removed from the
OFF.
charger after the LED lights. The GSE charger automatically
(2) Connect GSE charger to 110-120 Vac power
stops charging after the LED lights.
source using the 110 Vac power cord (6).
(7) Set GSE charger power switch to OFF
(3) Ensure that the receiver power switch is set to
OFF.
(a) If properly charged, the battery is ready
(4) Connect charger cables to each of the receiver
to use.
(b) If battery will not charge after standard
(5) Connect the other end of the charge cables to
rate charging, discard battery.
the appropriate fast or normal charge receptacles on the GSE
(9) Disassemble charge cables and store with the
charger. Before fast charging, charge battery on normal
GSE charger.
charge for five minutes.
Figure 2-35. Battery charging for receiver and servo/battery group batteries.