TM 9-2320-279-10-2
M984E1 General Operating Procedures (Cont)
(1) Remove cover (1) from REMOTE CONTROL CONNECTOR outlet (2) and
clean any dirt or water from outlet.
WARNING
Make sure ON/OFF/MHC-SHUTDOWN power switch is in
OFF position before connecting REMOTE CONTROL
UNIT. Crane moving out of control could cause serious
injury or death.
(2) Clean any dirt or water from cable connector (3) and connect
connector to REMOTE CONTROL CONNECTOR outlet (2).
(3) Turn ON/OFF/MHC-SHUTDOWN power switch (4) on REMOTE
CONTROL UNIT (5) to ON position.
2-97