TM 9-2320-366-10-2
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e17f.
OIL PRESS GAGE DOES NOT ILLUMINATE (CONT).
(c)
(d)
Position main light switch selector lever to SER DRIVE (para 2-27c).
(e)
Position main light switch auxiliary lever to PNL BRT (para 2-27c) and observe if OIL PRESS
gage illuminates.
(f)
If OIL PRESS gage does not illuminate, notify Unit Maintenance.
(g)
Position main light switch auxiliary lever to OFF (para 2-27c).
(h)
Position main light switch main selector lever to OFF (para 2-27c).
AUXILIARY PANEL, PERSONNEL HEATER, AND INSTRUMENT PANEL DO
NOT
ILLUMINATE.
Check circuit breaker (CB23) in PDP to see if it is tripped.
(a)
(b)
Position main light switch to OFF (para 2-27c).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position main light switch to SER DRIVE (para 2-27c).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position main light switch to OFF (para 2-27c).
(g)
(h)
If auxiliary panel, personnel heater, and instrument panel still do not illuminate, notify Unit
Maintenance.
Check to see if hazard lights switch illuminates.
(a)
Position main light switch main selector lever to SER DRIVE (para 2-27c).
(b)
Position main light switch auxiliary lever to PNL BRT (para 2-27c) and observe if hazard lights
switch illuminates.
(c)
Position main light switch auxiliary lever to OFF (para 2-27c).
(d)
Position main light switch main selector lever to OFF (para 2-27c).
Change 1