Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TRANSMISSION AUXILIARY OIL COOLER FAN DOES NOT OPERATE (ALL MODELS
EXCEPT M1088/M1089).
Check circuit breaker (CB68) in PDP to see if it is tripped.
(a)
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-27a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-27f).
(g)
(h)
If transmission auxiliary oil cooler fan still does not operate, notify Unit Maintenance.
M1088/M1089 TRANSMISSION AUXILIARY OIL COOLER FAN DOES NOT OPERATE.
Check circuit breaker (CB68) in PDP to see if it is tripped.
(a)
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-27a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-27f).
(g)
(h)
If transmission auxiliary oil cooler fan still does not operate, notify Unit Maintenance.
M1088/M1089 WORKLIGHTS DO NOT ILLUMINATE.
Check circuit breaker (CB72) in PDP to see if it is tripped.
(a)
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-27a or b).