TM 9-2330-205-14&P
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Wear protective goggles to prevent eye injury when opening
air reservoir draincock. Step away from airstream.
1. Air reservoir (1)
Draincock (2)
Open and relieve all pressure.
Close when finished.
2. Relay valve (3)
Four lines (4)
Using 5/8- and 7/8-inch open-end
wrenches, disconnect.
3. Mount (5)
Two nuts (6), two
Using two 9/16-inch open-end
wrenches, remove. Take out relay
and two bolts (8)
valve (3).
INSTALLATION
4. Mount (5)
Position on mount (5).
5. Mount (5)
Two nuts (6), two
Using two 9/16-inch open-end
wrenches, install.
and two bolts (8)
6. Relay valve (3)
Four lines (4)
Using 5/8- and 7/8-inch open-end
wrenches, connect.
TA223337