TM 9-2330-246-14
4-24. 208-VOLT POWER ENTRY PANEL CONNECTOR REPLACEMENT (M348A2H)
(Con't).
INSTALLATION
c.
1.
Solder wires to back of connector (9). Remove tags. Position insulator over wires and connector.
Install connector (9) in panel assembly (10) using four screws (15), new lockwashers (14), and nuts (13).
2.
Secure connector cover to panel assembly (10) using screw (7), two flatwashers (8), new Iockwasher (11), and
3.
nut (12).
Close and secure power entry cover plate (6).
4,
From inside semitrailer, connect wires from connector (9) to terminal board (5) and tighten screws. Remove
5.
tags.
Install new gasket (2) on cover plate (4) using adhesive.
6.
Install cover plate (4) on cover assembly (1) using 14 screws (3).
7.
TA700173
4-40