TM 9-2330-246-14
4-24. 208-VOLT POWER ENTRY PANEL CONNECTOR REPLACEMENT (M348A2H)
(Con't).
From outside semitrailer, open power entry cover plate (6) and secure in open position.
4.
Remove nut (12), lockwasher (11), two flatwashers (8), and screw (7) securing connector cover to panel
5.
assembly (10). Discard Iockwasher.
Remove four nuts (13), Iockwashers (14), and screws (15) from connector (9). Remove connector from panel
6.
assembly (10). Discard Iockwashers.
Pull insulator back over wires to expose soldered wire connections. Tag and unsolder wires from connector (9).
7.
b.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
The solvent's flash point is 100F-138F (38C-590C). If you become dizzy while
using cleaning solvent, immediately get fresh air and medical help. If solvent contacts
eyes, immediately wash your eyes and get medical aid.
1.
Clean all parts with dry cleaning solvent. Dry thoroughly.
Inspect parts for cracks, breaks, or other damage. Replace defective parts.
2.
Ensure that gasket mating surface of junction box cover plate is clean, dry, and free of residue.
3.
TA700172
4-39