TM 9-2330-271-14&P
CHAPTER 9
MAINTENANCE OF AUXILIARY EQUIPMENT
Section I. ORGANIZATIONAL MAINTENANCE
with two model CE60VAL6, 208volt, three-phase, 60 Hz,
9-1. General
60, 000 BTU air conditioners, mounted on the front
platform. The control panels are located on the right side
This chapter describes the auxiliary equipment used with
wall near the partition.
some of the semitrailers. Procedures are included for
removal and installation of this equipment.
(1) Remove the two access panels from front
wall in the interior of van, beneath the plenum chamber
9-2. Air conditioner, XM654
partition.
a. General. The XM654 semitrailer is equipped
Figure 9-1. Air conditioner and remote control unit, XM654
(2) Disconnect both power and remote control
(6) Remove screws which run through centers
cables. Place cables so that they hang into van through
of shock mounts, and remove air conditioner unit.
the access opening and are taut against front wall of van,
c. Installation (fig. 91).
out of the way of air conditioner units.
(1) Position air conditioner on shock mounts
(3) Loosen both large hexagonal cap screws
and secure in place with the screws which run through
on each hood assembly.
the centers of the shock mounts.
(4) Unscrew cap screws which hold hood
(2) Position hood assembly using the two large
assembly in place against van wall.
hexagonal cap screws on each hood assembly as
(5) Unscrew 16 cap screws from rivnuts and
positioning guides.
remove hood.
(3) Thread 16 cap screws into the nuts with
blind rivets and tighten.