TM 9-2330-356-14
(7) Capacity indicator may he adjusted as follows:
(a) Locate the semitrailer on level ground.
(10) Remove grounding clip from grounding stud
on top of tank. Store and cover fire extinguishers.
(b) Ensure that tank is empty.
b.
(c) Fill the tank by metering in 5000 gallons
of fuel.
(d) Loosen the jam nut and screw the round
(2) Ensure that all valves are closed.
level indicator up or down, as required, until the fuel level
just touches the bottom of the indicator. Hold indicator
firmly and tighten the jam nut. No further adjustment
(4) Remove cover from bottom loading connec-
should be required.
tion. Connect bottom loading hose to bottom loading
(8) Remove fill hose. Close and secure manhole
connection (fig. 2-22 and 2-11 or 2-12). Have fire extin-
fill cover. Install padlock.
guishers ready.
Figure 2-22. Typical Bottom Loading Flow
Diagram for All Models (M967
and M967A1 Arrangement
Shown).