TM 9-2330-384-14&P
5-6. CABINET REPLACEMENT (Con't).
a. REMOVAL
(1)
(2)
Approximately 1 ft. (30.5 cm) back from rear wall of cabinet (7), cut two tubings (1).
(3)
If required, to allow removal of tubing pieces (3 and 11), file burred ends of two cables (2)
inside cabinet (7).
NOTE
Mark tubing pieces (3 and 11) to ensure proper installation.
(4)
Remove tubing pieces (3 and 11) from cabinet (7).
(5)
Unscrew two nuts (5) from straight adapters (6).
WARNING
Cabinet (7) Is heavy and awkward to handle. Use caution, provide adequate
support, and use assistance during removal. Failure to follow this warning
may result in serious Injury to personnel.
(6)
Place a suitable floor jack under cabinet (7).
5-17